Ophthalmic Visual Field Analyzer YSMD-820A
Item No.: YSMD-820A
Ophthalmic Visual Field Analyzer for sale with good price
| Product parameters | |
| Brand: | YSENMED |
| MOQ: | 1 |
| Package: | Wooden Package |
| Ship From: | Guangzhou |
| Lead Time: | 1-3 days |
| Customization: | Yes |
Description
Ophthalmic Visual Field Analyzer YSMD-820A

Features:
Ø Configuration of the perimeter: computer, printer, table and main unit of the perimeter
Ø Clinical practicality, Superior function & Understandable report
Ø Accurate, stable & economical
Parameters:
| Specifications | |
| Type: | Hemispherical Bowl Type (Radius 300 mm) |
| Stimulus Size: | Φ2mm |
| Stimulus light source: | LED |
| MD-820 Measuring Area | 1. 10° stimulus (62 point), red |
| 2. 30° stimulus (76 point), (wave 585nm) | |
| 3. 30° ~ 60°stimulus (60 point), (wave 585nm) | |
| 4. 60° stimulus (76 point), (wave 585nm) | |
| 5. Glaucomatous sensitive damage area, (Nasal step), on left and right side of stimulus (16 point), (wave 585nm) | |
| 6. 60° ~ 90° each side of stimulus 11 points, (wave 585nm) | |
| Total point 256 (including blind spot detection) | |
| Stimulus Intensity: | 0.5 ~ 318nt (1.6 ~ 1000asb) |
| Stimulus Duration: | 0.1sec, 0.2sec, 0.5sec |
| Stimulus Interval: | 0.5sec, 1.0sec, 2.0sec |
| YSMD-820 patient fixation monitoring | Type 1 blind spot monitoring, warning for non-fixation |
| Type 2 blind spot monitoring, warning, image and sound indication for non-fixation | |
| Voice indication and guidance, guide patient to be detected correctly | |
| In order to enhance the reliability, the technician can choose special point for reexamination | |
| Test Reports | 1. Digital graph |
| 2. Two-Dimensions (Gray-scale) graph: 10°, 30°, 30° ~ 60° | |
| 3. Symbol graph, quantitive test report | |
| 4. MS, MD, Total loss, Average loss, Blind spot detection, corrected probability | |
| Statistical Analysis (T-test) available besides statistical graph | |